Height | 690 mm, 27in |
Depth | 582 mm, 23in |
Width | 970 mm, 38in |
Weight | 150 kg, 331lbs |
Throughput | 400 photometric tests per hour, 240 ISE tests per hour. Combined throughput of 560 tests per hour. |
Analyser accreditation | CE marking in compliance with In Vitro Diagnostic Medical Device Directive 98/79/EC, FDA 510k cleared and UL certification (4~15 ºC) |
Analyser type | Compact fully automated random access bench top clinical analyser |
Assay tests | Endpoint, kinetic, biochromatic, turbidmetric, sample blanking, reagent blanking and ISE |
Maintenance | Daily maintenance-less than 5 minutes. No rear access required. Simple twice yearly preventative maintenance service |
Data management | Storage of up to 30,000 patient reports, search facility, test counter |
Test channels | 60 photometric channels, 3 direct ISE tests - sodium, potassium and chloride |
Sleep mode | User defined sleep mode capabilities with automatic wash and instrument prep |
Reagent capacity | Removable tray with 60 cooled positions (30 positions for 100 or 50ml bottles and 30 positions for 20ml bottles) |
Reagent cooling | 8-15°C |
Reagent identification | Automatic barcode reagent identification |
Reagent inventory | Calculation of remaining reagent volume and tests available, alert for shortage, expired reagent and expired calibration |
Reagent pipette | Dedicated twin reagent micropipette with liquid level sensor and crash detection, rinsed inside and outside with purified water |
Sample addition | Immediate sampling interruption for addition of samples via removable panel |
Sample capacity | Removable tray with 72 positions for samples, 20 cooled position for controls and calibrators |
Sample dead volume | 150µl in standard or primary tubes, 100µl in paediatric cups |
Sample dilution | Pre-dilution and automatic re-assay with diluted, reduced or increased sample volume. Dilution mixture 100 -350µl consisting of 2-35µl of sample and 20-350µl of diluent |
Sample identification | Barcode sample identification |
Sample pipette | Dedicated sample micropipette with liquid level sensor, crash detection, bubble detection and 4 levels of clot detection. Rinsed inside and outside with purified water |
Sample tube Size | Multiple primary tube sizes (diameter 13 to 16mm, height 75 to 100 mm), paediatric cups |
Sample type | Serum, Plasma, Urine, Supernatant & Whole Blood |
Sample volume | 2 to 35µl (0.1µl increments) |
STAT sampling | mmediate STAT sampling interruption |
Minimum reaction volume | 150µl |
Stirring speed | Dual 5-speed rotating stirrers rinsed with purified water |
Stirring system | Paddle type rotating stirrer cleaned with purified water |
Temperature | 37°C±0.3 |
Cuvettes | 90 reusable Pyrex® cuvettes with 5-year lifespan, min volume 150µl, Max volume 450µl, 8-stage cuvette washing system |
Cuvette size | 8(W) x 6.23(D) x 30(H) mm |
Cycle time | 9 seconds |
Water consumption | 18L per hour |
Water requirements | NCCLS type 1 or 2 purified water supply at pressure [0.15-0.34Mpa] |
Detector method | Direct absorbance in cuvette (bichromatic and monochromatic) |
Detection principal | 12 wavelengths: 340, 380, 415, 450, 510, 546, 570, 600, 660, 700, 750 and 800 nm |
ISE tests | Integrated ISE unit |
Light source | Halogen tungsten lamp (air-cooled, 6 months service life) |
Quality contro | Interactive Levey-Jennings Charts, Daily, Monthly and Batch QC with data archiving, Automatic QC and Automatic calibration |
Calibration principal | Factor, Linear, point to point, spline, log-logit and exponential. Up to 7 calibrators per test |
Input voltage | 100 - 240 Vac |
Power consumption | <900 VA |
UPS requirements | 1230 W (analyser and PC) |
LIMS connectivity | Bi-directional; ASTM standard (RS232 connection) |
Operator interface | 15” LCD display and printer externally connected. Windows® based user Interface 100 -249 VAC, 1230 Watt approx |